Place of Origin : Beijing , Beijing , China (mainland)
Brand Name : GFUVE
Model Number : GF106
Category : CURRENT TRANSFORMER TEST EQUIPMENT
Sample Price : Depending on the market supply and demand
Delivery Time : 7 working days
Certification : EPRI, KEMA, CE, ISO9001:2008.
Measuring Energy Range : 0-220V, 0-20A
Accuracy Class : 0.05%
Operating Temperature : -20~+70°C
Display Type : Digital Only
Phase : Single Phase
FUNCTION : CT PT TEST
CT RATIO : 1-10000
PHASE ACCURACY : 4MIN
MOQ : 1SET
Price : USD20000-35000
Packaging Details : Standard export box
Payment Terms : T/T, Western Union, Paypal
Supply Ability : 200pcs/month
Application
To protect class or measuring kind of transformer characteristics (CT and PT) for automatic test, suitable for the laboratory also applies to the field detection.
GF106: test CT and PT
GF106A: test CT
GF106B: test PT
Reference Standard
GB 1207-2006, GB 1208-2006 (IEC 60044-1), GB16847-1997 (IEC 60044-6)
Main features
• Support to detect CT (protection type, measuring kind, TP class) steady state and transient parameters;
• To use advanced frequency conversion power technology, (current-voltage characters) excitation inflection point voltage up to 30 KV;
• No external other auxiliary equipment, single machine can complete all testing project;
• Using intelligent controller, simple operation;
• LCD, graphical display interface;
• According to the regulations, automatically give (excitation) inflection point value;
• Automatically give 5% and 10% error curve;
• saving 3000 test data, not lost after power off;
• Support U plate archived data, using a standard PC to read data,and produce WORD report;
• small light ≤10 Kg, it is very easy to the field test;
• Support to detect the error of PT at the same time.
Main functions
CT (PT) (protection type, measuring kind, TP class)
• current-voltage characters curve (excitation characteristic)
• automatically give inflection point value
• automatically give 5% and 10% of the error curve
• variable ratio measurement
• Ratio error measurement
• phase angle measurements (angular)
• polar judgment
• the secondary winding resistance measurements
• two times the actual load measurement
•Core demagnetization,
• accurate limit coefficient (ALF)
• instrument security coefficient (FS)
• second time constant (Ts)
• residual magnetism coefficient (Kr)
• saturated and unsaturated inductance
Technical Data
Project Parameter
Power supply AC220V±10% ,50Hz
Equipment output 0~150Vrms, 5Arms(15Apeak )
Voltage measurement accuracy ±0.1%
The secondary
winding Resistance measurements range 0~50Ω
accuracy 1%±1mΩ
Two times the actual Load measurement range 0~300VA
accuracy 1%±0.1VA
Phase measurement
(angular) accuracy ±3min
resolution 0.3min
CT Variable ratio measurement range 1-10000
accuracy
±0.05%
PT Variable ratio measurement range 1-10000
accuracy ±0.05%
Work environment Temperature:-10 ℃ ~ 40 ℃, humidity:≤ 90% or altitude ≤1000 m
Size, weight Size: 380 mm x 240 mm x 180 mm, weight: ≤10 kg